We ship fast! All orders leave our warehouse within one business day.Specifications:
Measure range: 0.00 - 14.00PH
Resolution: 0.01PH
Accuracy: ±0.01 PH (at 25℃)
Power Supply: 2*1.5V (LR44 Included)
Operating Temperature: 0℃ - 80℃ (32℉ - 176℉)
Dimension: 155mm* 31mm * 18mm / 6.10”×1.22”×0.70”
Weight: 50g / 1.76oz
Calibration:
1. Turn on the pH meter.
2. Dissolve each buffer solution in 250 ml of distilled water.
3. Immerse the electrode into the pH 6.86 solution (under the temperature of 25℃).
4. Press the “CAL”(calibration) button for 5 seconds and release;
- Display screen will start flashing “6.86”;
- Wait for it until the display screen stops flashing;
- Rinse the electrode with distilled water and make it dry with filter paper.
5. Repeat the above steps with 4.01 pH buffer powder and 9.18 pH buffer powder.
Note:
Calibration is required in the following conditions.
- Lengthy periods of inactivity
- Very frequent use
- The testing accuracy requirement is very high
- The “cal” key was pushed and the electrode was exposed to air for an extended period of time
Package Includes:
1×pH Meter
3×pH Buffer Powder
1×User's Manual
Specifications:
Measure range: 0.00 - 14.00PH
Resolution: 0.01PH
Accuracy: ±0.01 PH (at 25℃)
Power Supply: 2*1.5V (LR44 Included)
Operating Temperature: 0℃ - 80℃ (32℉ - 176℉)
Dimension: 155mm* 31mm * 18mm / 6.10”×1.22”×0.70”
Weight: 50g / 1.76oz
Calibration:
1. Turn on the pH meter.
2. Dissolve each buffer solution in 250 ml of distilled water.
3. Immerse the electrode into the pH 6.86 solution (under the temperature of 25℃).
4. Press the “CAL”(calibration) button for 5 seconds and release;
- Display screen will start flashing “6.86”;
- Wait for it until the display screen stops flashing;
- Rinse the electrode with distilled water and make it dry with filter paper.
5. Repeat the above steps with 4.01 pH buffer powder and 9.18 pH buffer powder.
Note:
Calibration is required in the following conditions.
- Lengthy periods of inactivity
- Very frequent use
- The testing accuracy requirement is very high
- The “cal” key was pushed and the electrode was exposed to air for an extended period of time
Package Includes:
1×pH Meter
3×pH Buffer Powder
1×User's Manual
Estimated between and
Will usually ship within 1 business day.Specifications:
Measure range: 0.00 - 14.00PH
Resolution: 0.01PH
Accuracy: ±0.01 PH (at 25℃)
Power Supply: 2*1.5V (LR44 Included)
Operating Temperature: 0℃ - 80℃ (32℉ - 176℉)
Dimension: 155mm* 31mm * 18mm / 6.10”×1.22”×0.70”
Weight: 50g / 1.76oz
Calibration:
1. Turn on the pH meter.
2. Dissolve each buffer solution in 250 ml of distilled water.
3. Immerse the electrode into the pH 6.86 solution (under the temperature of 25℃).
4. Press the “CAL”(calibration) button for 5 seconds and release;
- Display screen will start flashing “6.86”;
- Wait for it until the display screen stops flashing;
- Rinse the electrode with distilled water and make it dry with filter paper.
5. Repeat the above steps with 4.01 pH buffer powder and 9.18 pH buffer powder.
Note:
Calibration is required in the following conditions.
- Lengthy periods of inactivity
- Very frequent use
- The testing accuracy requirement is very high
- The “cal” key was pushed and the electrode was exposed to air for an extended period of time
Package Includes:
1×pH Meter
3×pH Buffer Powder
1×User's Manual
Estimated between and
Will usually ship within 1 business day.